- installation convenience: can be installed in 35 mm DIN rail;
- easy to operate, through the amplifier integrated keys and digital tube to set each parameter;
- rich parameter configuration: multiple input instruction type can be configured, the maximum, minimum, slope of rise and fall time, frequency, flutter instruction dead zone, the median adjustment, etc.;
- wide wide voltage and current: 8 ~ 32 VDC wide voltage input, 0 ~ 3 a wide output current, can meet various demand of the double proportion electromagnet valve position feedback;
- fault diagnosis: break, overload of instruction, electromagnet break, over current real-time monitoring, and in digital tube display the current fault codes, easily locate fault point;
EHC - RS485 communication interface: cooperate with PC software - Manager, can realize batch parameter modification and remote monitoring, etc;
- support the Modbus RTU protocol: can realize multimachine communication control;